Hydratec Inc.

AutoCAD Based (Cleanup)

Total: 12

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
View (card-1180) Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

When starting the Pretty Pipes command, you get an Unhandled Exception error including 'Could not find a part of the path'

 

Another error mentions blockoffsets.dat

 

View (card-995) Cleanup (AutoCAD Based) Draw Pretty Pipes None Einvalidlayer

Starting the Pretty Pipe process, you get this error;

Unhandled exception has occurred...  eInvalidLayer

View (card-912) Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Unhandled Exception has occurred in a component in your application.

One of the identified items was in an invalid format

View (card-527) Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Unhandled Exception has occurred in a component in your application

Index was out of range. Must be non-negative and less than the size of the collection.

View (card-508) Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

User drew own entities in FLEXPIPE Layer. That layer is only to be used by HydraCAD Unhandled Except. V50

View (card-503) Cleanup (AutoCAD Based) Draw Pretty Pipes None None

An invalid pretty pipe color was used in the setup and the program cannot re-open the Pretty Pipe dialog box JIT debugging Dialog box n/a

View (card-499) Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Pretty Pipes requires line type TRACKS. This line type is missing from the drawing. Unhandled Except. v50

View (card-472) Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Bad PRETTYPIPES.DAT file

2. corrupt xrefs

3. Irregular linetypes in the drawing.

4. Bad Hcad_Toolbox.dll file eBadLinetypName V53.04

View (card-438) Cleanup (AutoCAD Based) Cloud None None

The cloud command does not finish correctly, when user right-clicks to close it. Cloud Command

View (card-386) Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Corrupt external data 2. 3D Head Block set wrong. show fittings HydraCAD V5x

Page: